Model MG2-640 MG2-300
Printing Method Piezo ink-jet method
Media Width 335 to 1,625 mm (13.2 to 64 in.) 182 to 762 mm (7.2 to 30 in.)
Thickness Max. 1.0 mm (39.3 mil) with liner, for printing
Max. 0.4 mm (15.7 mil) with liner and 0.22 mm (8.6 mil) without liner, for cutting
Roll outer diameter Max. 250 mm (9.8 in.)
Roll weight Max. 45 kg (99 lb.) Max. 30 kg (66 lb.)
Core diameter 76.2 mm (3 in.) or 50.8 mm (2 in.)
Printing/cutting width (*1) Max. 1,600 mm (62.9 in.) Max. 736 mm (28.9 in.)
Ink type UV Ink [EUV5EP / D-UA2P] 1,000 ml pouch
Ink colors EUV5EP Eight colors (Cyan, Magenta, Yellow, Black, Gloss, White, Orange, and Red)
Seven colors (Cyan, Magenta, Yellow, Black, White (2 pouches), Orange, and Red)
Six colors (Cyan, Magenta, Yellow, Black, Gloss (2 pouches), and White (2 pouches))
Four colors (Cyan, Magenta, Yellow, and Black)
D-UA2P Six colors (Cyan, Magenta, Yellow, Black, Gloss (2 pouches), and White (2 pouches))
Four colors (Cyan, Magenta, Yellow, and Black)
Ink-curing unit Built-in UV-LED lamp
Printing resolution (dots per inch) Max. 1,800 dpi
Cutting speed 10 to 300 mm/s (0.39 to 11.8 in./s)
Blade force (*2) During operation 30 to 500 gf
Blade Type Roland CAMM-1 series blade
Offset 0.000 to 1.500 mm (0.0 to 59 mil)
Software resolution (when cutting) 0.025 mm/step (0.98 mil/step)
Media heating system (*3) Front heater set temperature: 30 to 55 °C (86 to 131 °F)
Connectivity Ethernet (100BASE-TX/1000BASE-T, automatic switching)
Power-saving function Automatic sleep feature
Rated input 100-120/220-240 Va.c. 50/60 Hz 5.3/2.7 A 100-120/220-240 Va.c. 50/60 Hz 4.1/2.0 A
Power Consumption During operation Approx. 700 W Approx. 550 W
Sleep mode Approx. 65 W
Acoustic Noise Level During operation 66 dB (A) or less
During standby 62 dB (A) or less
Dimensions
(width x depth x height)
2,902 mm × 748 mm × 1,412 mm
(114.3 in. × 29.5 in. × 55.6 in.)
2,038 mm × 748 mm × 1,412 mm
(80.3 in. × 29.5 in. × 55.6 in.)
Weight 210 kg (463 lb.) 165 kg (364 lb.)
Environment During
operation (*4)
Temperature: 20 to 32 °C (68 to 89.6 °F), Humidity: 35 to 80 % RH (no condensation)
Not
operating
Temperature: 5 to 40 °C (41 to 104 °F), Humidity: 20 to 80 % RH (no condensation)
Included items Dedicated stand, power cord, media take-up unit, media holders, replacement blade for separating knife, cleaning liquid bottle for maintenance, drain bottle, User’s Manual, software (VersaWorks, Roland DG Connect), etc.
  1. *1Operating environment (use in an operating environment within this range.)
  2. *2•500 gf is the maximum instantaneous blade force.
  3. •The blade force must be adjusted according to details such as the media thickness.
  4. *3•Warm-up is required after power up. This may require 5 to 20 minutes, depending on the operating environment.
  5. •Depending on the ambient temperature and media width, the preset temperature may fail to be reached.
  6. *4Operating environment (Use in an operating environment within this range.)